三维电极法处理六硝基茋生产废水  被引量:3

Treatment of Hexanitrostilbene Production Wastewater by Three-dimensional Electrode Process

在线阅读下载全文

作  者:任雅琴[1] 李峰[2] 李瑞博[1] 朱晓宏[2] 

机构地区:[1]兰州大学资源与环境学院,甘肃兰州730000 [2]中北大学化工与环境学院,山西太原030051

出  处:《化工环保》2014年第1期28-31,共4页Environmental Protection of Chemical Industry

摘  要:以Ti板为阴极、Ti/IrO2-Ta2O5电极为阳极,采用三维电极法处理六硝基茋生产废水。通过单因素实验和正交实验确定的最佳工艺条件为:电解电压8 V,电解时间4 h,极板间距5 mm,初始废水COD=3 120 mg/L,m(玻璃珠)∶m(活性炭)=1∶3(选定活性炭的质量为5.0 g),ρ(硫酸钠)=500 mg/L。在此最佳工艺条件下,废水COD去除率为36.5%。Hexanitrostilbene production wastewater was treated by three-dimensional electrode process using Ti plate as cathode and Ti/IrO2-Ta2O5 electrode as anode. Based on the results of single factor experiments and orthogonal experiments,the optimum process conditions are determined as follows:electrolysis voltage 8 V,electrolysis time 4 h,plate spacing 5 mm,initial wastewater COD 3 120 mg/L,m(glass bead)∶m(activated carbon)=1∶3(with 5.0 g of the activated carbon mass),ρ(sodium sulfate)=500 mg/L. Under these conditions,the COD removal rate is 36.5%.

关 键 词:三维电极 六硝基茋 废水处理 

分 类 号:X703[环境科学与工程—环境工程]

 