检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:冯志军[1]
机构地区:[1]张家港华兴电力有限公司,江苏张家港215627
出 处:《电力与能源》2014年第1期67-71,共5页Power & Energy
摘 要:在对张家港市主城片区建设燃气热电联产机组替代燃煤小热电必要性分析的基础上,结合当地实际情况,阐述选择F级燃气—蒸汽联合循环热电联产机组的可行性,并对当前F级燃气热电联产机组的主流机型、性能和特点进行分析,进而提出燃气热电联产机组选型方案。分析认为,主机设备装机方案的选择,不仅要从机组的经济技术角度考虑,还要考虑整个机组运行高效、安全、可靠、灵活、供热连续等诸多因素,更要考虑投产后运行维护和检修费用,只有全面进行分析与比较,才能做出合理的选择。Based on analysis of the necessity of small coal-fired thermal power instead of Jiangsu Zhangjiagang City area construction of gas cogeneration units, further combined with the local actual situation, the feasibility of F gas steam combined cycle cogeneration unit, the mainstream models, properties and characteristics of the F class gas cogeneration units were analyzed, and then put forward the selection scheme of gas power generation units. The analysis thinks, the scheme is the selection of the main equipment, not only to consider the unit from the economic point of view of technology, but also consider the whole operation efficiency, safe, reliable, flexible, heating continuous and many other factors, but also to take into account the operation and maintenance and the maintenance cost is put into production, only the comprehensive analysis and comparison, we can make a reasonable choice.