有无隔断装置对冷风机热气融霜的影响  被引量:3

Influence of the partition board on the hot-gas defrosting of air-cooler

在线阅读下载全文

作  者:王栋[1,2] 陶乐仁[1] 

机构地区:[1]上海理工大学能源与动力工程学院,上海200093 [2]安徽工业大学建筑工程学院,马鞍山243002

出  处:《低温与超导》2014年第2期56-58,61,共4页Cryogenics and Superconductivity

基  金:高等学校博士学科点专项科研基金(博导类联合)(20103120110002)

摘  要:冷风机表面积霜后会使换热效率急剧下降,所以必须及时地对冷风机表面进行除霜处理。不管用何种除霜方法,总会有部分热量散到周围环境,这不但使能量有所损失,而且还破坏了周围的温度场。为了解决这个问题,设计了一个隔断装置,通过不同工况的实验,研究增加融霜隔断装置对热气融霜过程中冷库库温变化、融霜结束时冷风机周围温度场分布、融霜能耗的影响,并通过与未增加隔断装置的相关实验进行分析对比,得出一些结论。The surface of air - cooler has frost, heat exchanger efficiency will fall sharply, so we must deal with the cooler surface to defrost in time. No matter what defrosting method we use, ihere will always be some heat to the surrounding environ- ment, which causes not only loss of energy, but also damages the surrounding temperature field. In order to solve this problem, we designed a partition board. Many experiments in different cold storage temperature were done, and inner temperature of cold storage with time, finished temperature field around air - cooler and defrosting energy were analyzed. Through the comparison with the corresponding experiments without partition board, some decisions were gotten.

关 键 词:除霜 隔断装置 节能 热气融霜 温度场 

分 类 号:TB657.1[一般工业技术—制冷工程]

 