摘 要:AEC—I型自动排气控制仪(AutomaticExhaustContr01)可与真空泵配套使用排除水氡观测闪烁室内的残留氡气。该仪器性能稳定、操作简单,能够对闪烁室自动按“排气-抽真空-再排气-再抽真空”顺序循环操作,还可以根据需要调节“排气-抽真空”状态的循环时间,提高排气效率,排气后的闪烁室本底达到《规范》要求,并在面板上实现了排气时间可视化。在该仪器试运行期间,对仪器的稳定性、真空时间和排气时间对排气效果的影响、仪器连续使用时间对排气效果的影响、与手动排气结果对比等方面进行测试分析,结果认为:AEC—I型自动排气控制仪控制精度高,性能稳定,对闪烁室的排气效果达到规范要求,可以作为水氡观测辅助设备用于闪烁室的排气工作。The AEC--I automatic exhaust control instrument with a vacuum pump can be used to exclude rudimental radon from water radon scintillation chamber. The device has the characteris- tics of stable performance, simple operation and in scintillation chamber it can be automatically and circularly operated in order of "exhaust--vacuum--exhaust again--vacuum again". It can al- so adjust the cycle time of "exhaust--vacuum" status according to the need and improve the ex- haust efficiency. After exhausting, the background of scintillation chamber can achieve the re- quirement of "standard", and we can visualize the exhaust time on the device panel. During the trial operation of the device, many factors are analyzed, such as the stability of device, the influ- ence of vacuum time and exhaust time on exhaust effect, the influence of continuous service time on the exhaust effect, the contrast with results of manual exhaust and so on. The results show that: AEC-I automatic exhaust control instrument has high precision on control, stable perform- ance, and its exhaust effect in scintillation chamber can meet the requirements of specification, so it can be used as the water radon observation auxiliary device in the exhaust of scintillation cham- ber.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7