600MW超临界空冷机组冷态启动过程优化  被引量:2

Optimization of Cold Start-up Process of 600 MW Supercritical Air Cooling Unit

在线阅读下载全文

作  者:宋立斌[1] 刘兴晖[1] 

机构地区:[1]华能国际电力股份有限公司上安电厂,石家庄050310

出  处:《河北电力技术》2013年第B12期6-8,共3页Hebei Electric Power

摘  要:针对600MW超临界空冷机组冷态启动过程能耗高的问题,提出使用汽泵前置泵上水、有效利用等离子点火装置、提高高压缸预暖温度、缩短冷态冲洗时间、合理投用空冷岛等冷态启动优化措施,分析优化效果,认为这些措施在保障安全的前提下,降低了启动能耗。The paper analyzes the high energy consumption of the original supercritical air cooling unit in the cold start-up process ,proposes the optimized measures such as :supplying water by steam pump preset pump to the boilers ,effectively using the plasma ignition device ,raising the pre-heat temper-ature of the high pressure cylinders ,reducing the cold wash-ing time ,employing the air cooling island reasonably in win-ter ,etc ,analyzes the optimization effects ,this paper consid-ers that the measures can reduced energy consumption on the premise of safety .

关 键 词:600MW超临界空冷机组 冷态启动 空冷岛 启动能耗 优化 

分 类 号:TM621[电气工程—电力系统及自动化]

 