作 者:刘兴晖[1] 任江波[1] 马力[1] 郭大民[1]
机构地区:[1]华能国际电力股份有限公司上安电厂,石家庄050310
出 处:《河北电力技术》2013年第B12期9-11,共3页Hebei Electric Power
摘 要:介绍华能国际电力股份有限公司上安电厂600 M W机组凝结水系统概况,针对除氧器上水调门局部阻力较大,造成节流损失的问题,提出在50%~100%负荷时,保持除氧器上水调门及其旁路电动门全开的方法,并从经济性、安全性两方面分析该方法的经济效益和节能效果,认为该方法节能效果显著。This paper describes the 600 MW unit and conden-sate water system of Huaneng Power International Inc . Shang'an Power Plant ,aiming at a larger local resistance caused higher throttling losses at bypass electric valve of de-aerator feed water control valve ,proposes a method to reduce throttling losses by opening the bypass electric valve of de-aerator feed water control valve under the load of 50% ~100% ,and analyzes the safety ,economy ,and considers that economic benefit and the energy-saving effect of this method is remarkable .
关 键 词:凝结水系统 凝结水泵 除氧器上水调门 旁路电动门 变频
分 类 号:TK264.12[动力工程及工程热物理—动力机械及工程]