检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]玉林市第一人民医院放射科,广西玉林537000
出 处:《医疗卫生装备》2014年第2期81-82,141,共3页Chinese Medical Equipment Journal
摘 要:目的:探讨消除对比剂伪影干扰颈部血管显示的方法。方法:将46例患者随机分为A、B 2组,扫描参数和重建参数均相同,A组23例,B组23例。使用双筒高压注射器,经肘正中静脉注入,2组病例的对比剂用量均为50 mL,流率5.0 mL/s,生理盐水50 mL。A组采用与对比剂相同的5.0 mL/s的流率推注冲管生理盐水;B组采用高于对比剂流率的方式,以6.0 mL/s的流率推注冲管生理盐水。结果:46例均能显示颈动脉、椎动脉及其主要分支,A组23例锁骨静脉残留对比剂的浓度普遍偏高。B组21例锁骨下静脉腔内存留的对比剂被稀释,不形成干扰伪影,效果良好;2例有对比剂残留,对比剂浓度已降低。结论:加快冲管盐水的推注能有效降低锁骨下静脉对比剂的残留浓度,达到淡化的效果,消除对比剂产生的伪影。Objective To eliminate the effect of the contrast artifact on displaying cervical vesseles. Methods There were 46 patients divided into Group A and Group B equally, with constant scanning parameters and reconstruction parameters. Binoculors pressure syringe was used to inject the agent and contrast through median cubital vein. The contrasts in the two groups had their dosage as 50 mL, flow rate as 5.0 mL/s and the saline dosage as 50 mL. The agent in Group A had the same flow rate as that of the contrast, and the one in Group B bad its flow rate as 6.0 mL/s. Results All the cases had their carotid arteries, vertebral arteries and their branches displayed clearly. The 23 ones in Group A had the concentration of the contrast remained in the subclavian vein increased, while 21 ones in Group B had the contrast diluted and no artifact appeared, and the remained 2 ones had the concentration decreased. Conclusion The increased flow rate of the injected saline can decrease the concentration of the remained contrast, and thus the artifact can be eliminated. [Chinese Medical Equipment Journal, 2014,35 (2): 81-82,141 ]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222