基于恒压加载的正压氧气呼吸器呼吸阻力分析  被引量:1

Breathing Resistance Analysis of Positive Pressure Oxygen Respirator Based on Constant Pressure Loading

在线阅读下载全文

作  者:钟伟 

机构地区:[1]中煤科工集团重庆研究院有限公司,重庆400039

出  处:《煤矿安全》2014年第3期113-115,共3页Safety in Coal Mines

摘  要:提出了气囊恒压加载式正压氧气呼吸器,对比测试了气囊恒压加载和弹簧加载的呼吸阻力。试验结果表明:气囊恒压加载产生的呼吸阻力比弹簧加载产生的小,并且其呼吸阻力波动幅值也比弹簧加载产生的小。当气囊载荷增大,呼吸量增大时,呼吸阻力增大;当气囊载荷减小,呼吸量减小时,呼吸阻力减小。This article proposes a balloon constant pressure - loaded positive pressure oxygen respirator and comparatively tests the breathing resistance value of balloon constant pressure - loaded respirators and spring - loaded respirators. The test results show that the breathing resistance value of balloon constant pressure - loaded respirators is lower and the amplitude of breathing resistance is smaller compared with spring - loaded respirators. When the load or the breathing capacity increased, the breathing resistance in- creased. When the load or the respiratory intensity reduced, the breathing resistance reduced.

关 键 词:正压氧气呼吸器 呼吸阻力 弹簧加载 恒压加载 试验分析 

分 类 号:TD774[矿业工程—矿井通风与安全]

 