黄村分矿10111工作面隐伏陷落柱特大突水原因分析及防治措施  被引量:3

Reasons Analysis and Prevention Measures of Water Bursting From Hidden Subsided Column in Huangcun Branch Coal Mine 10111 Working Face

在线阅读下载全文

作  者:俞宏庆[1] 邢文平[1] 

机构地区:[1]河南煤化焦煤集团科研所,河南焦作454002

出  处:《煤矿安全》2014年第3期183-185,共3页Safety in Coal Mines

摘  要:通过奋进煤矿黄村分矿10111工作面隐伏陷落柱特大突水原因分析,实施了封堵突水点、地面三维地震勘探、地面钻探、井下物探、局部注浆加固等多项针对性强的水害防治对策,为矿井防治水工作提供了科学依据。Through reasons analysis of water bursting from hidden subsided column at 10111 working face in Huangcun Branch of Fen- jin Coal Mine, the study implemented a targeted water damage prevention measures, including plugging water bursting point, three - dimensional seismic exploration, ground drilling, underground geophysical exploration, partial grouting which provided a scientific ba- sis for prevention and control of mine water disaster.

关 键 词:隐伏陷落柱 底板含水层 突水 寒灰 水害 

分 类 号:TD745[矿业工程—矿井通风与安全]

 