检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Ke-rui Guo Su-yun Xiang Jiang-bo Sun 孟长功
机构地区:[1]Department of Chemistry,Dalian University of Technology
出 处:《Chinese Journal of Polymer Science》2014年第3期315-320,共6页高分子科学(英文版)
摘 要:Functional polymers such as polyethylene grafted glycidyl methacrylate (PE-g-GMA) and ethylene-methyl acrylate-glycidyl methacrylate terpolymer (E/MA/GMA) were used as compatibilizers in the preparation of highly filled composites of polyethylene/magnesium hydroxide(PE/MH). Comparative studies were performed on the effect of magnesium hydroxide and stearic acid on the interface within polymer and magnesium hydroxide composites. The effect of polymeric compatibilizers on the properties of the composites was studied using tensile and impact tests, torque rheological analysis, differential scanning calorimetry and environmental scanning electron microscopy (ESEM). The microstructure of highly filled PE/MH composites changed after the addition of functional polymers. The mechanical properties of the composite material increased after compatibilization. The compatibilization processes of PE-g-GMA and E/MA/GMA were different. The grafted polymer was more compatible with polyethylene, which led to a polar polymer phase. In contrast, the tercopolymer tended to adhere to the surface of MH particles.Functional polymers such as polyethylene grafted glycidyl methacrylate (PE-g-GMA) and ethylene-methyl acrylate-glycidyl methacrylate terpolymer (E/MA/GMA) were used as compatibilizers in the preparation of highly filled composites of polyethylene/magnesium hydroxide(PE/MH). Comparative studies were performed on the effect of magnesium hydroxide and stearic acid on the interface within polymer and magnesium hydroxide composites. The effect of polymeric compatibilizers on the properties of the composites was studied using tensile and impact tests, torque rheological analysis, differential scanning calorimetry and environmental scanning electron microscopy (ESEM). The microstructure of highly filled PE/MH composites changed after the addition of functional polymers. The mechanical properties of the composite material increased after compatibilization. The compatibilization processes of PE-g-GMA and E/MA/GMA were different. The grafted polymer was more compatible with polyethylene, which led to a polar polymer phase. In contrast, the tercopolymer tended to adhere to the surface of MH particles.
关 键 词:GMA Grafted polymer CO-POLYMER POLYETHYLENE Magnesium hydroxide.
分 类 号:TB33[一般工业技术—材料科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.12.34.36