山东省地方性氟中毒病区X线检查成像质量的评价  被引量:1

Evaluation of imaging quality of X-ray films of endemic fluorosis in Shandong Province

在线阅读下载全文

作  者:张霞[1] 李亨祥[1] 陈培忠[1] 翟丽萍[1] 

机构地区:[1]山东省地方病防治研究所甲状腺疾病防治中心,济南250014

出  处:《中华地方病学杂志》2014年第2期216-219,共4页Chinese Journal of Endemiology

基  金:山东省医药卫生科技发展计划资助项目(2013WS0175、HL086);中央补助地方公共卫生专项资金地方病防治项目(2008);济宁市科技发展计划资助项目(2009-56)

摘  要:目的评价山东省地方性氟中毒(地氟病)病区x线检查成像质量,为正确实施x线检查提供依据。方法在山东省20个地氟病县(市、区)各选择3个病村作为调查点,X线拍摄村民的前臂(包括肘关节)和小腿(包括膝关节)正位片,每村拍摄20张,每张包括2个拍摄部位。其中14个县(市、区)的42个病村X线检查由山东省地方病防治研究所承担,共拍摄X线片840张,编为A组,其余6个县(市、区)由当地医院拍摄X线片360张,编为B组。依照检查技术要求和诊断指标来确定X线片审片项目,分照片表面缺陷、结构缺陷、综合质量三个层面对比观察A与B组X线片质量差异。结臬在照片表面缺陷评定中,A组缺陷指标总检出率前臂片为7.98%(67/840),小腿片为9.77%(82/840);B组分别为35.27%(127/360)和39.16%(141/360),两组比较差异有统计学意义(x。值分别为138.6、144.0,P均〈0.01)。在照片结构缺陷评定中,A组结构缺陷总检出率前臂片为7.14%(60/840),小腿片为8.33%(70/840);B组分别为27.22%(98/360)和31r38%(113/360)。两组比较差异有统计学意义(x。值分别为88.867、103.6,P均〈0.01)。在照片综合质量评定中,A组优质率前臂片为72.73%(611/840),小腿片为71.67%(602/840),而质差率分别为9.89%(83/840)和11.43%(96/840):B组优质率为44.14%(159/360)和42.22%(152/360),质差率为34.74%(125/360)和38.06%(137/360),两组比较差异有统计学意义(Z值分别为-20.161、-16.229,P均〈0.01)。结论由县(市、区)自拍摄的X线片缺陷较多、图像较差,其原因与当地医院X线技师技术水平参差不齐,照片质量要求不严有关,应定期成立上级专业技师监管队伍,到现场督导摄片和审片,推行以防治单Objective To evaluate the photo quality of X-ray films of endemic fluorosis in Shandong Province, and to provide a basis for correct implementation of X-ray examination. Methods Three villages were selected as survey sites in each of the 20 endemic fluorosis counties (cities, districts) of Shandong Province; anteroposterior X-ray films of the villagers forearm (including elbow) and leg (including knee) were taken; 20 films were taken in each village, each film comprising two recording sites. X-ray examination carried out in the 42 patients' villages of 14 counties(cities, districts) were undertaken by the Institute for Endemic Disease Control, Shandong Province, a total of 840 X-ray films shoot, which was edited group A, and the remaining six counties (cities, districts) were undertaken by the local Hospital, shooting X-ray films 360 copies, compiled for group B. The quality of X-ray film examination was determined in accordance with technical requirements and diagnostic indicators. The difference of photo quality between group A and group B was compared at three levels : sub-surface defects photos, structural defects and comprehensive quality. Results In evaluation of surface defects in the photo, the total detection rate of the defects indicators in group A of forearm was 7.98%(67/840), while the rate of leg was 9.77% (82/840). And the rates of group B were 35.27% (127/360) and 39.16% (141/360), respectively, and the differences were statistically significant between the two groups(xforearm = 138.6, P 〈 0.01 ; Xleg = 144.0, P 〈 0.01 ). In assessment of structural defects, the total forearm defection rate of group A was 7.14%(60/840), and the leg was 8.33%(70/840). And the rates of group B were 27.22% (98/360) and 31.38%(113/360), respectively. The differences were statistically significant(x2 forearm = 88.867, P 〈 0.01; X2leg = 103.6, P 〈 0.01). In the photo quality comprehensive assessment, the excellent rate of forearm in group A was 72.7

关 键 词:氟化物中毒 氟骨症 X线 

分 类 号:R599[医药卫生—内科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象