摘  要:针对合流制管网溢流污染严重的现状,提出了新型的合流管网错时分流技术,通过旱流调蓄实现雨天时对生活污水进行调蓄,最大程度减少雨天时合流管网系统中生活污水中污染物的溢流排放;进而结合某小区管网特征以及当地降雨资料进行了应用研究,并分析了该工程的投资及环境效益。According to the present situation of overflow pollution to combined piping network, this study proposes a new type of time staggered shunt technology of combined piping network, in which the domestic sewage in rainy days is regulated through dry flow storage to minimize overflow discharge of pollutants in sewage of combined piping network system. Based on the pipe network characteristics of a housing estate and the local rainfall data, its applications are studied, as well as its in vestment and environmental benefits.