摘  要:针对直接膨胀式地源热泵单U埋地换热器的传热特性,建立换热器及周围土壤温度场的数学物理模型。模拟计算分析制冷剂进口温度、钻孔几何尺寸与回填材料等因素对单U埋地换热器周围土壤温度的影响。研究结果为合理设计直接膨胀式地源热泵提供了理论参考。A mathematic-physical heat transfer model for single U-type underground heat exchanger and peripheral soil temperature field was established based on the heat transmission characteristics of the underground heat exchanger of the direct expansion ground source heat pump. The influences of the inlet (import) temperature of the refrigerant, drilled size and backfill materials on the soil tem- perature were analysed. The results may provide guidance for the design of the direct expansion ground source heat pump.