防弧金具在高海拔10kV绝缘导线的应用  

Application of Arc-protection for 10 kV Overhead Insulation Lines at High Altitude Area

在线阅读下载全文

作  者:冯彦钊[1] 龚石林[1] 张明[2] 

机构地区:[1]云南电网公司,昆明650011 [2]华中科技大学电气工程学院,武汉430074

出  处:《云南电力技术》2014年第1期1-4,共4页Yunnan Electric Power

摘  要:提出了用韦伯概率分布模型处理多次放电数据的方法,按照绝缘子串耐受且防弧金具间隙击穿的概率达到99.85%的标准来设计间隙距离,该方法准确、易操作。通过试验,得到了昆明高海拔地区(海拔2 000 m)10 kV架空绝缘导线P15针式绝缘子加装防弧金具的间隙距离。The method of processing several discharge voltages' data using Weibull probability plot model is presented, According to the standand that probability of insulator string tolerance and arc - protection hardware gap breakdown achieve 99. 85% to design the gap distance. The method has the eharaeteristics of accuracy and easy to operate. By test results, the best gap distance of arc - protection hardware used for 10 kV overhead insulation lines and P15 pin insulators is 9. 5 cm. The result provides methods and ex- periment basis for the application of arc - protection hardware at high altitude areas.

关 键 词:防弧金具 架空绝缘导线绝缘配合 韦伯分布 高海拔地区 

分 类 号:TM862[电气工程—高电压与绝缘技术]

 