平衡环境型房间量热计凝结水量测量设计  被引量:1

The Design of Condensate Measurement for Balanced Ambient Room-type Calorimeter

在线阅读下载全文

作  者:柳胜耀[1] 李瑛[1] 黄彩凤[1] 赵四海[1] 

机构地区:[1]上海理工大学,上海200093

出  处:《制冷学报》2014年第2期106-110,共5页Journal of Refrigeration

摘  要:量热计法室内侧制冷量计算公式,未考虑测量中小冷量空调器制冷量时空气处理柜除湿造成的误差。为排除此误差对测试结果的影响,采用称重法分别测量量热计内、外室加湿水及被测机的凝结水。利用基于称重法设计的量热计测得5台被测机的2组数据并进行分析,结果表明,当空调器的额定制冷量低于测试室输入功率时,空气处理柜的除湿量会增大测量偏差,且随着空调器制冷量的降低偏差增大。并对室内侧制冷量计算公式进行修正,以提高计算精确度。During the cooling capacity measurement of small and medium size air conditioner, the indoor cooling capacity calculation formula of room-type calorimeter didn' t take the dehumidification of air handling cabinet into consideration. In order to eliminate the impact of this influence on the test results, the mass weighing method was proposed to measure the humidification water of inner and outer chamber of the calorimeter, as well as the condensate water of air conditioner under test respectively. Two sets of test of five units were conducted by means of room-type calorimeter based on the mass weighing method. It turns out that, when the rated cooling capacity of the air conditioner under test is smaller than the input power of the test chamber, the test error is increased by the air handling cabinet' s dehumidification amount, and the test error rises with the decrease of cooling capacity of air conditioner. The indoor cooling capacity calculation formula is modified to improve its accuracy according to the test results.

关 键 词:房间型量热计 称重法 凝结水测量 实验验证 

分 类 号:TH811[机械工程—仪器科学与技术] TB611[机械工程—精密仪器及机械]

 