检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华中科技大学电气与电子工程学院,湖北武汉430074 [2]浙江省电力公司衢州电力局,浙江衢州324000 [3]湖北省电力公司武汉供电公司,湖北武汉430013
出 处:《华中科技大学学报(自然科学版)》2014年第3期68-72,共5页Journal of Huazhong University of Science and Technology(Natural Science Edition)
基 金:国家科技支撑计划资助项目(2008BAC36B00)
摘 要:将大型冲击电流发生器运至现场,在实际的线路杆塔上给接地装置注入模拟雷电冲击大电流,测量接地装置对地电位升高、冲击接地电阻等指标,获得了运行中杆塔的接地装置冲击特性参数.同时应用接地装置仿真计算模型,按照与现场试验相同的条件用电磁暂态分析程序(ATP-EMTP)进行了仿真计算,将计算结果和试验结果进行了对比分析,取得了较好的一致性.The large impulse current generator was delivered to the site,and large simulation lightning current was injected into actual grounding devices of transmission line tower.The potential rise and impulse grounding resistance were measured,and the impulse characteristic parameters of the transmission line tower grounding were obtained.A simulation model of grounding was presented,and the simulation was taken by the ATP-EMTP(ATP-electromagnetic transients program)following the field tests.Comparison between the results of tests and simulation also is completed,and the consistency is good.
关 键 词:输电线路杆塔 接地装置 雷电冲击电流 电位升高 冲击接地电阻 现场试验
分 类 号:TM86[电气工程—高电压与绝缘技术]
正在载入数据...