滨海电厂循环水泡沫起因分析及解决方案  被引量:3

The Analysis of the Causes and Solutions to the Foam of Circulating Cooling Water of Coastal Power Plant

在线阅读下载全文

作  者:龙宏斌[1] 

机构地区:[1]广东红海湾发电有限公司,广东汕尾516623

出  处:《电站辅机》2014年第1期31-34,共4页Power Station Auxiliary Equipment

摘  要:近年来,环境的污染问题被日益受到重视,某滨海电厂冷却水排水口处出现泡沫污染问题,影响了周边的自然环境。为此,对循环水产生泡沫的起因进行了分析,提出了加装斜板堆、拦泡墙及消泡喷淋管、设置缓坡溢流堰、增加柔性膜覆盖层等措施,采用这类解决方案后,能够有效减轻滨海电厂循环水排水口处泡沫的污染问题。In recent years, the pollution of environment have been more concerned, the foam problem of the circulating cooling water outlet of coastal power plant also caused some troubles. The paper analyzes the cause of the circulating cooling water foam and put forward several solutions: Installing Inclined plates,Installing a wall can hold bubbles and some pipes can spray water to destroy bubbles.set the slope overflow weir.Installing a layer of flexible film covering on the surface of the water, which can effectively reduce the foam pollution of the circulating cooling water outlet of coastal power plant.

关 键 词:滨海电厂 循环水 虹吸井 排水 泡沫 污染 分析 方案 

分 类 号:TM621[电气工程—电力系统及自动化]

 