检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李青[1,2] 宋光林 谭红 何锦林 魏赫楠[1,2]
机构地区:[1]贵州省分析测试研究院,贵州贵阳550002 [2]贵州大学,贵州贵阳550000
出 处:《冶金分析》2014年第2期15-19,共5页Metallurgical Analysis
基 金:国家科技部创新方法专项([2011]IM030700);贵州省省长基金项目(黔省合字[2012]19号);贵州大学研究生创新基金(研理工2013013)
摘 要:比较了液-液萃取气相色谱测定精四氯化钛水解样品中四氯化碳方法中使用的庚烷、正己烷、正辛烷、异辛烷4种萃取剂对痕量四氯化碳的萃取效果。结果表明:4种萃取剂对四氯化碳都有较好的响应,色谱图上的峰位和峰形都较好,而且四氯化钛中三氯甲烷、一氯乙酰氯、三氯乙酰氯共存杂质对四氯化碳的测定没有干扰。对于庚烷、正己烷、正辛烷、异辛烷,校准曲线的线性相关系数分别为0.990 8、0.997 2、0.998 7、0.999 5,检出限分别为0.003 2、0.0015、0.004 4、0.001 1,样品加标平均回收率分别为95.4%、98.8%、96.4%、99.6%,相对标准偏差分别为2.6%、4.0%、4.6%、1.6%。因此,4种萃取剂对四氯化碳都有较好的萃取能力,但异辛烷的萃取能力最强,稳定性也较好。The extraction effects of four extractants liking heptane, n-hexane, n-octane and iso-octane used for the extraction of trace carbon tetrachloride in the determination trace carbon tetrachloride in the hydrolytic sample of refined titanium tetrachloride by liquid-liquid extraction gas chromatography were compared. The four extractants all exhibited fine response to carbon tetrachloride and gave good peak positions and peak shapes in the chromatograms. The coexisting impurities including chloro- form, chloroacetyl chloride and trichloroacetyl chloride in titanium tetrachloride didn't interfere in the determination of carbon tetrachloride. For heptane, n-hexane, n-octane and iso-octane, the linear cor- relation coefficients of the calibration curves were 0. 990 8, 0. 997 2, 0. 998 7 and 0. 999 5, the detec- tion limits were 0. 003 2, 0. 001 5, 0. 004 4 and 0. 001 1, the sample standard average recoveries were 95.4 , 98.8 , 96.4 and 99.6 and the relative standard deviations were 2.6 , 4.0 , 4. 6 and 1.6 , respectively. Thus, the four extractants all had satisfactory extraction capacity for carbon tetrachloride, but iso-octane had the best extraction capacity and better stability.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.120