检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张达[1] 杨艳玲[1] 李星[1] 相坤[1] 刘扬阳[1]
机构地区:[1]北京工业大学北京市水质科学与水环境恢复工程重点实验室,北京100124
出 处:《化工学报》2014年第4期1424-1428,共5页CIESC Journal
基 金:国家自然科学基金项目(51178003);北京市自然科学基金项目(8122013)~~
摘 要:为保证长距离输水管道输送水水质,采用管道模拟反应器考察了溶解氧(DO)对输水管道水质影响以及曝气充氧后水质恢复情况。结果表明:DO降低影响氨氮(NH+4-N)的去除,DO浓度越低越不利于NH+4-N的去除,且曝气充氧后恢复越缓慢,DO=0.5 mg·L-1和DO=1.5 mg·L-1的反应器在运行95 h后,NH+4-N去除率分别由90%降到21%和85%,曝气充氧54 h和3 h后恢复;DO浓度降低导致亚硝酸氮(NO-2-N)积累明显增加,DO浓度越低,NO-2-N的积累越严重,且曝气充氧后恢复越缓慢,DO=0.5 mg·L-1的反应器在运行95 h后,出水NO-2-N由0.02 mg·L-1增加到0.354 mg·L-1,曝气充氧54 h后恢复,DO=1.5 mg·L-1的反应器在运行32 h后,出水NO-2-N达到最大值0.112 mg·L-1,曝气充氧4 h后恢复;DO浓度降低使水中UV254升高,DO=0.5 mg·L-1和DO=1.5mg·L-1的反应器在运行2 h后,出水UV254分别增加了70.8%和20.8%,均在运行32 h后恢复,且曝气充氧后保持稳定。因此,DO对长距离输水管道水质具有重要影响,可采用DO实现对水质的调控。To ensure the water quality in long distance pipeline transportation, the influence of dissolved oxygen (DO) on water quality and recovery process after aeration oxygenation were studied in a pipeline reactor that could simulate this long distance pipeline transportation. The results showed that the decrease of DO could reduce + the removal of ammonia nitrogen (NH4-N), and the lower DO concentration was the more unfavorable removal of + + NH4-N, the slower recovery after aeration oxygenation was. The removal rate of NH4-N declined from 90% to 21% and 85% after reactor run 95 h at DO=0.5 mg . L-1 and 1.5 mg .L-1, and the recovery after aeration oxygenation took 54 h and 3 h respectively. The accumulation of nitrite nitrogen (NO2--N) increased significantly as DO reduced, and the lower DO concentration was the more favorable accumulation of NO2--N, the slower recovery after aeration oxygenation was. At DO=0.5 mg.L-1 nitrite nitrogen increased from 0.02 mg .L-1 to 0.354 mg -L-1 after reactor run 95 h, and the recovery after aeration oxygenation took 54 h. While the maximum value of nitrite nitrogen was 0.112 mg . L-1 after reactor run 32 h at DO=1.5 mg. L-1, and the recovery after aerationoxygenation took only 4 h. The decrease of DO concentration could lead to rise of UV254. UV254 increased by 70.8% and 20.8% after reactor run 2 h at DO=0.5 mg . L-1 and 1.5 mg . L-1,respectively, and both recovery took 32 h, and then it was relatively stable after aeration oxygenation. Therefore, DO is of important impact on water quality in long distance pipeline transportation, and could used for the regulation of water quality.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.185