Effects of Plasma Aerodynamic Actuation on Corner Separation in a Highly Loaded Compressor Cascade  被引量:1

Effects of Plasma Aerodynamic Actuation on Corner Separation in a Highly Loaded Compressor Cascade

在线阅读下载全文

作  者:王学德 赵小虎 李应红 吴云 赵勤 

机构地区:[1]Science and Technology on Plasma Dynamics Laboratory,Air Force Engineering University

出  处:《Plasma Science and Technology》2014年第3期244-250,共7页等离子体科学和技术(英文版)

基  金:supported by National Natural Science Foundation of China(Nos.50906100,10972236);Foundation for the Author of National Excellent Doctoral Dissertation of China(No.201172)

摘  要:This paper reports experimental results on the effects of plasma aerodynamic actua- tion (PAA) on corner separation control in a highly loaded, low speed, linear compressor cascade. Total pressure loss coefficient distribution was adopted to evaluate the corner separation control effect in wind tunnel experiments. Results of pressure measurements and particle image velocime- try (PIV) show that the control effect of pitch-wise PAA on the endwall is much better than that of stream-wise PAA on the suction surface. When both the pitch-wise PAA on the endwall and stream-wise PAA on the suction surface are turned on simultaneously, the control effect is the best among all three PAA types. The mechanisms of nanosecond discharge and microsecond discharge PAA are different in corner separation control. The control effect of microsecond discharge PAA turns out better with the increase of discharge voltage and duty cycle. Compared with microsec- ond discharge PAA, nanosecond discharge PAA is more effective in preventing corner separation when the freestream velocity increases. Frequency is one of the most important parameters in plasma flow control. The optimum excitation frequency of microsecond discharge PAA is 500 Hz, which is different from the frequency corresponding to the case with a Strouhal number of unity.This paper reports experimental results on the effects of plasma aerodynamic actua- tion (PAA) on corner separation control in a highly loaded, low speed, linear compressor cascade. Total pressure loss coefficient distribution was adopted to evaluate the corner separation control effect in wind tunnel experiments. Results of pressure measurements and particle image velocime- try (PIV) show that the control effect of pitch-wise PAA on the endwall is much better than that of stream-wise PAA on the suction surface. When both the pitch-wise PAA on the endwall and stream-wise PAA on the suction surface are turned on simultaneously, the control effect is the best among all three PAA types. The mechanisms of nanosecond discharge and microsecond discharge PAA are different in corner separation control. The control effect of microsecond discharge PAA turns out better with the increase of discharge voltage and duty cycle. Compared with microsec- ond discharge PAA, nanosecond discharge PAA is more effective in preventing corner separation when the freestream velocity increases. Frequency is one of the most important parameters in plasma flow control. The optimum excitation frequency of microsecond discharge PAA is 500 Hz, which is different from the frequency corresponding to the case with a Strouhal number of unity.

关 键 词:plasma aerodynamic actuation corner separation COMPRESSOR CASCADE 

分 类 号:O53[理学—等离子体物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象