艾氏卡法测定全硫各影响因素的深入研究  被引量:8

Research on influencing factors when using Aishika method to determine the total sulfur

在线阅读下载全文

作  者:张津铭[1,2] 武增礼[1,3] 

机构地区:[1]煤炭科学研究总院煤炭分析实验室,北京100013 [2]煤炭资源高效开采与洁净利用国家重点实验室,北京100013 [3]国家煤炭质量监督检验中心,北京100013

出  处:《煤质技术》2014年第2期48-50,共3页Coal Quality Technology

摘  要:介绍了艾士卡法测定全硫的基本原理,并以实际比对试验为例,对影响全硫测定准确度的因素进行了研究。研究结果表明:采用艾士卡法测定全硫过程中,可从煤与艾氏剂的反应程度、洗液总体积、盐酸用量、沉淀剂用量及滴加速度、陈化及灰化过程等方面采取相应的措施,以确保全硫测定的准确性。This paper introduced the basic principles of using Aishika method to determine the total sulfur of coal, taking the practical comparison test as example, influencing factors which affected the accuracy of determination of the total sulfur were studid, it was shown that: in the process of using aldrine card method to determine the total sulfur, we could adopt some corresponding measurements from aspects such as reaction degree of coal and aldrine, the total volume of washing fluid, the amount of hydrochloric acid and precipitation agentdropping speed, ageing and podzolic process to make sure the accuracy of determination.

关 键 词:艾士卡法 全硫 影响因素 准确度 

分 类 号:TQ533.1[化学工程—煤化学工程]

 