检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:叶春燕[1] 兰新生[1] 王志高[1] 周易谦[1] 林巧红[1] 刘虹[1]
机构地区:[1]国网四川省电力公司电力科学研究院,四川成都610072
出 处:《四川电力技术》2014年第2期81-85,共5页Sichuan Electric Power Technology
摘 要:在电力企业厂界噪声监测工作中,存在背景噪声难以测量和修正的问题。提出了点声源随距离衰减模型,并基于"非同时性"、监测指标、运行工况等对测量方法进行了改进。针对被测噪声和背景噪声的差值小于3和不为整数的噪声值、稳态或非稳态的情况进行了修正,对实际工作具有一定的指导作用。In the actual boundary noise monitoring of electric power enterprises, the problems exists that the background noise is difficult to be measured and corrected. A sound source level with distance attenuation model is proposed, and the measure- ment method is improved based on the "non -simultaneity" , monitoring indicators, operating condition and so on. Some cor- rections are carried out for the measured noise and background noise which is less than 3 and for the noise value which is not an integer as well as the steady and unsteady noise, which has a guide meaning for the actual work.
关 键 词:厂界噪声 背景噪声 修正 等效声级 频谱特性分析
分 类 号:X839[环境科学与工程—环境工程]