熔盐冷却高温球床堆中Flibe对栅元均匀化群截面的影响  

Effect of Flibe Molten Salt on Cell-homogenized Group Cross-section in PB-FHR

在线阅读下载全文

作  者:秦威[1,2] 梅龙伟[2] 王小鹤[2] 蔡翔舟[2] 陈金根[2] 

机构地区:[1]中国科学院大学,北京100049 [2]中国科学院上海应用物理研究所,上海201800

出  处:《原子能科学技术》2014年第4期673-679,共7页Atomic Energy Science and Technology

基  金:中国科学院战略性先导科技专项资助项目(XDA02010200)

摘  要:熔盐冷却高温球床堆与高温气冷堆所用冷却剂不同,其中子学性能会影响栅元均匀化群截面。本文基于MCNP5研究Flibe熔盐对238 U、235 U、232 Th共振能区栅元均匀化群截面的影响,并与高温气冷堆进行对比。结果表明,由于熔盐的引入,238 U、235 U、232 Th的栅元均匀化群截面在包含较强共振峰的能群会发生明显改变,238 U、232 Th栅元均匀化吸收群截面增大,235 U栅元均匀化裂变群截面减小。随燃料填充度与熔盐填充度的增加,熔盐对所研究重核素的栅元均匀化群截面的影响增大;燃料运行温度与燃料富集度的变化,对Flibe引入的截面相对变化影响并不明显。计算结果表明,熔盐对栅元均匀化裂变群截面和均匀化吸收群截面的影响具有一定规律性。The neutronics performance of coolant for a pebble bed fluoride salt cooled high temperature reactor(PB-FHR)plays an important role on the cell-homogenized group cross-section,and it is different from the case in high temperature gas-cooled reactor(HTGR).The effect of Flibe on cell-homogenized group cross-section of 238 U, 235 U and 232 Th was investigated based on the MCNP5code.It is found that due to Flibe, the cell-homogenized absorption cross-section changes sharply compared with that of the helium coolant in the energy group containing strong resonance peak.The cellhomogenized absorption group cross-section gets bigger for 238 U and 232 Th,while the cell-homogenized fission group cross-section gets smaller for 235 U after including Flibe in the calculation.The relative change introduced by Flibe increases with the packingfactor of fuel and molten salt.It is also found that the fuel temperature and the fuel enrichment will not bring evident effect on the relative change.The results express the influence of Flibe on cell-homogenized absorption cross-section and cell-homogenized fission cross-section shows certain regularity.

关 键 词:FLIBE 熔盐 栅元均匀化群截面 相对变化 共振能群 

分 类 号:TL364.5[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象