环境侧风对300MW火电机组冷却塔影响的数值模拟  被引量:5

Numerical Simulation on Effect of Cross-wind to Cooling Tower of 300MW Thermal Power Unit

在线阅读下载全文

作  者:刘剑涛[1] 任建兴[1] 杨涌文[1] 李芳芹[1] 

机构地区:[1]上海电力学院能源与机械工程学院,上海200090

出  处:《汽轮机技术》2014年第2期115-118,共4页Turbine Technology

基  金:上海市教委重点学科(第五期)(J51304)

摘  要:以300MW机组双曲线自然通风冷却塔为研究对象,采用Fluent软件对冷却塔进行了三维数值模拟,分析了变工况下环境侧风对冷却塔冷却性能的影响、环境侧风对冷却塔进风口速度场的影响。研究发现:随着侧风风速的增加,冷却温差先减小后增大,出塔水温先增大后减小;并且,环境侧风的存在会扰乱冷却塔进风口流场,其临界风速值为6m/s。Taking a hyperbolic natural draft cooling tower of 300MW thermal power unit as research object, effect of cross- wind to cooling tower performance and air inlet velocity field are analyzed. These researches of numerical simulation are based on the Fluent Software. Researches show that cooling temperature difference will decrease first and then increase, outlet temperature of the tower will increase and then decrease with the increasing of cross-wind velocity. Air inlet velocity field of the cooling tower will be disturbed by the existence of the cross-wind, of which the critical wind speed is 6m/s.

关 键 词:数值模拟 冷却塔 环境侧风 冷却温差 进风口速度场 

分 类 号:TK264.1[动力工程及工程热物理—动力机械及工程]

 