机构地区:[1]国网天津市电力公司调度控制中心,天津300010 [2]国网西藏电力有限公司调度控制中心,西藏拉萨850000
出 处:《国网技术学院学报》2014年第1期11-15,19,共6页Journal of State Grid Technology College
摘 要:2013年初藏中电网内的乃琼、夺底、曲哥站完成SVC装置投运。如何对三站的SVC进行控制,保障电网安全成为了调度部门研究的重点。本文结合藏中电网实际,提出不基于通信的联合控制策略,并应用于电网实际运行中,取得了良好效果。At the beginning of 2013,the SVC devices had been configured in Naqiong,Duodi and Quge substations of the central Tibet Power Grid. The control on the SVC devices of the three substations and ensuring the operation safety of the power system,it became the research focus by the power dispatch departments. On the situation of the central Tibet Power Grid,an unified control strategy without communication has been proposed in this paper. It has been applied to the actual operation of the power grid, and achieved ~ood results.
关 键 词:静止无功电压补偿器(SVC) 电压 控制