作 者:LU WenYuan YIN XueFei LIU XiaoHui YAN GuoQuan YANG PengYuan
机构地区:[1]Department of Chemistry and Institutes of Biomedical Sciences, Fudan University
出 处:《Science China Chemistry》2014年第5期686-694,共9页中国科学(化学英文版)
基 金:supported by the National Basic Research Program of China(2010CB912700,2013CB911201,2011CB910600);the National High Technology Research and Development Program of China(2012AA020203,2014AAQ00361);the National Natural Science Foundation of China(21227805)
摘 要:High-throughput quantification with label-free methods has received considerable attention in electrospray ionization(ESI)-mass spectrometry(MS),but the manner by which MS signals respond to peptide concentration remains unclear in proteomics.We developed a new mathematical formula to describe the intrinsic log-log relationship between the MS intensity response and peptide concentration in an analytical ESI process.Experimental results showed that the calibration curve is fairly fit to the log-log formula with a linear dynamic range of approximate four to five orders of magnitude.However,we found that the ionization of analytical peptides can be severely suppressed by coexisting matrix peptides,such that the calibration curve can be poorly leveled off on both ends.Our study suggests that the interferences from coexisting matrix peptides should be reduced in the ESI process to use the log-log calibration curve successfully for the high-throughput quantification.High-throughput quantification with label-free methods has received considerable attention in electrospray ionization (ESI)- mass spectrometry (MS), but the manner by which MS signals respond to peptide concentration remains unclear in proteomics. We developed a new mathematical formula to describe the intrinsic log-log relationship between the MS intensity response and peptide concentration in an analytical ESI process. Experimental results showed that the calibration curve is fairly fit to the log-log formula with a linear dynamic range of approximate four to five orders of magnitude. However, we found that the ion- ization of analytical peptides can be severely suppressed by coexisting matrix peptides, such that the calibration curve can be poorly leveled off on both ends. Our study suggests that the interferences from coexisting matrix peptides should be reduced in the ESI process to use the log-log calibration curve successfully for the high-throughput quantification.
关 键 词:peptide quantification ESI-MS peptide intensity peptide concentration interference
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171