作 者:刘建新[1] 姜健[1] 王霄英[1] 曹新鸣[1] 盛程程 李美娇[1] 张来运 赵永为[1]
机构地区:[1]北京大学第一医院医学影像科,北京100034
出 处:《放射学实践》2014年第4期369-372,共4页Radiologic Practice
摘 要:目的:探讨100kVp条件下、头颈部CTA检查中碘克沙醇(270mgI/mL)个性化注射方案的成像效果。方法:连续50例患者行头颈部CTA检查。使用对比剂碘克沙醇(270mgI/mL),个性化对比剂注射方案如下:注射总量一体重(kg)×0.5mL/kg;根据注射时间的不同(分别为7、8和9s)将患者分为3组(4g次为A、B、C组);注射流率一注意总量/注射时间,规定最高流率为6mL/s;采用对比剂智能跟踪触发技术,兴趣区置于主动脉弓处,阈值为80HU。由两位阅片者对3组的重组图像进行主观评估(5分法),并测量颈部及脑内动脉的CT值。结果:三组患者的年龄、性别、身体质量指数(BMI)的差异无统计学意义(P〉0.05)。三组图像的主观评分分别为4.75±0.41、4.85±0.34和4.29±0.61,A组与B组主观评分的差异无统计学意义(P〉0.05),A组、B组与C组间主观评分的差异有统计学差异(P=0.004、0.024)。三组图像上颈动脉及脑内动脉的CT值:A组与B组间CT值的差异无统计学意义(P〉0.05),A组、B组与C组间CT值的差异有统计学差异(P=0.001~0.037)。结论:碘克沙醇(270mgI/mL)在头颈CTA检查中可进行个性化注射,图像质量可满足诊断需求。Objective:To evaluate the feasibility of head and neck CTA with 100kVp technique and individualization protocol of Iodixanol (270 mg I/mL) administration. Methods: 50 patients underwent head and neck CTA using Iodixanol (270mg I/mL) as contrast medium. The individual contrast medium protocol were as follows: total volume of contrast medium administrated: weight(kg) × 0.5mL/kg. According to different time period of injection, which were 7s, 8s and 9s, these patients were divided into 3 groups (Group A,Group B, Group C respectively);the injection rate: volume/injection time,with the highest rate as 6mL/s. Using smart tracing trigger technique for contrast injection, the region of interest (ROD was placed at aortic arch,the threshold was set as 80HU. The reformatted images were subjectively evaluated by 2 radiologists with 5 scale method, and the CT values of carotid artery and intra-cerebral artery were measured. Results: There were no significant statistic differences in gender, age and BMI among the 3 groups (P〉0.05). The image quality scores of Group A,Group B and Group C was 4. 75±0.41,4.85±0.34 and 4.29±0.61 respectively,no statistic difference was existed between Group A and Group B (P〉0.05) ,significant statistic difference was existed between Group A,Group B and Group C (P=0. 004 and 0. 024 respectively). Of the CT values of carotid arteries and intra-cerebral arteries of the 3 groups, no statistic difference was showed between Group A and Group B (P〉0.05), yet there were significant differences between Group A,Group B and Group C (P=0. 001 and 0. 037 respectively). Conclusion: Individualization of injection pro- tocol is feasible in head and neck CTA with iodixanol (270mg I/miL). The image quality can meet the requirement of diagnosis.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.8