内置百叶遮阳中空玻璃制品热工性能研究  被引量:5

Analysis of the Thermal Performance of Sealed Insulating Glass Unit with Blind inside in Shanghai Area

在线阅读下载全文

作  者:李峥嵘[1] 胡玲周[1] 赵群[2] 汪海生[3] 

机构地区:[1]同济大学机械与能源工程学院 [2]同济大学建筑与城市规划学院 [3]同济大学建筑设计研究院

出  处:《建筑热能通风空调》2014年第2期10-14,43,共6页Building Energy & Environment

基  金:"十二五"国家科技支撑计划(2011BAJ03B02-1)

摘  要:采用门窗遮阳计算软件WINDOW及能耗模拟软件Energy-plus,分析影响内置百叶遮阳中空玻璃制品热工性能参数U与SHGC的关键结构参数;并以上海市办公建筑为例,用单位面积外窗形成的采暖空调及照明总能耗为控制指标,给出各关键结构参数的建议取值,为上海地区内置百叶遮阳制品的设计与运行调节提供依据。The key factors that affecting the U and SHGC values of sealed insulating glass unit with blind inside were analyzed by the shading design software WINDOW and the building energy simulation software Energy-plus. The reference model of office building in shanghai was built up, annual air-conditioning system and lighting energy-saving application of this technique in Shanghai area. and the scope of threshold values of those factors based on rate were defined. It provides a basis for the design and

关 键 词:内置百叶遮阳 中空玻璃制品 热工性能参数 阈值 