检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王宏伟[1] 冯垚飞[1] 冯林魁[1] 谷志德[1] 王平[1] 张瑞山[1]
机构地区:[1]甘肃省电力公司电力科学研究院,甘肃兰州730000
出 处:《热力发电》2014年第4期106-109,共4页Thermal Power Generation
摘 要:通过某∏T-140/165-130/15-2型供热机组的抽汽试验,绘制了机组在实际抽汽工况下新蒸汽流量与电功率的关系(工况图),根据机组特性和实际热负荷,对工况图以及相应的试验数据进行分析并对不同抽汽流量下的功率进行修正,得出在不同热负荷下机组的调峰范围。研究结果表明:随着抽汽流量的增加,机组最小电功率随之增大,最大电功率先增大后减小;当抽气流量分别为60、120、180、240、300、360t/h时,机组的调峰范围分别为79.88、77.98、67.35、61.11、55.88、30.13 MW,即抽汽流量越大,机组的调峰范围越小。By steam extraction test on a T140/165130/152 type heating unit, the diagram re flecting relationship between the new steam flow rate and electric power under actual condition was drawn. Moreover,according to the unit's characteristics and actual heat load, the above dia gram and the corresponding test data were analyzed and the power at different extraction flow rates was revised. Thus the peak regulation range at different heat loads was obtained. The results show that:with an increase in extraction flow,the unit's minimum electric power rose,and the maximum electric power grew first and then decreased; when the extraction flow was 60 t/h, 120 t/h,180 t/h,240 t/h,300 t/h,and 360 t/h,the unit's peak regulation range was 79.88 MW, 77.98 MW,67.35 MW,61.11 MW,55.88 MW and 30.13 MW,respectively,namely the higher of the extraction flow, the smaller of the unit's peak regulating range.
分 类 号:TK212[动力工程及工程热物理—动力机械及工程]
正在载入数据...