作 者:LIU Sujuan ZHUO Li JIANG Wenshu ZHANG Meihui
机构地区:[1]College of Electronic Information and Control Engineering, Beijing University of Technology
出 处:《Chinese Journal of Electronics》2014年第1期75-80,共6页电子学报(英文版)
基 金:supported by the National Natural Science Foundation of China(No.61106028);in part by the Scientific Research Project of Beijing Educational Committee(No.KM201110005006)
摘 要:Time-interleaved analog-to-digital converter(TIADC) is an efficient way to achieve higher sampling rate for medium-to-high resolution applications. The performance of a TIADC suffers from the mismatch errors among the sub-channels. This paper presents a method to estimate the channel mismatches using the sub-channels output data. The proposed method introduces an equivalent transfer function for each channel to model and estimate the mismatch errors. A Hybrid filter bank(HFB)structure is used to both model the TIADC and reconstruct the desired uniformly sampled sequence based on the perfect reconstruction conditions of the HFB system.A four-channel 12-bit 400 MHz TIADC has been implemented in hardware to verify the proposed calibration method. The measured results show that the Spuriousfree dynamic range(SFDR) can be improved up to 74 d B after being corrected with 64-tap Finite-impulse response(FIR) filters.Time-interleaved analog-to-digital con- verter (TIADC) is an efficient way to achieve higher sam- pling rate for medium-to-high resolution applications. The performance of a TIADC suffers from the mismatch errors among the sub-channels. This paper presents a method to estimate the channel mismatches using the sub-channels output data. The proposed method introduces an equiv- alent transfer function for each channel to model and es- timate the mismatch errors. A Hybrid filter bank (HFB) structure is used to both model the TIADC and recon- struct the desired uniformly sampled sequence based on the perfect reconstruction conditions of the HFB system. A four-channel 12-bit 400MHz TIADC has been imple- mented in hardware to verify the proposed calibration method. The measured results show that the Spurious- free dynamic range (SFDR) can be improved up to 74dB after being corrected with 64-tap Finite-impulse response (FIR) filters.
关 键 词:Time-interleaved (TI) Analog-to-digitalconverter (ADC) Channel mismatch Hybrid filter bank(HFB).
分 类 号:TN792[电子电信—电路与系统] TN713
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.88