检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:姜宁[1]
机构地区:[1]中国移动通信集团江苏有限公司南京分公司,江苏南京215009
出 处:《现代建筑电气》2014年第3期10-14,共5页Modern Architecture Electric
摘 要:随着移动通信的发展,远端设备的供电问题亟需解决。对射频单元(RRU)及远端设备的三种供电方案:市电直接供电、市电+不间断电源(UPS)供电、直流远程供电系统进行了对比。直流远程供电系统可降低管理及运维成本,并可减少意外停电造成的损失。通过工程实例证明,远程供电系统的供电方式完全满足现行形势下通信设备的各种运用场景,值得运用与推广。With the development of mobile communication, remote equipment of the power supply problem need to be solved. Three kinds of power supply scheme of RRU and the remote equipment, such as mains powered directly, mains + UPS power supply, DC remote power supply system were compared. DC remote power supply system could reduce the cost of management and operations, and reduce the loss caused by unexpected power outages. And through the engineering example, it proved that the remote power supply system of power supply can completely satisfy the various use of the current situation of communications equipment scene, it is worth applying and popularizing.
关 键 词:移动通信 远端设备 远程供电系统 建设要点 成本
分 类 号:TN929.5[电子电信—通信与信息系统]