出 处:《现代建筑电气》2014年第3期41-45,共5页Modern Architecture Electric
摘 要:通过对蓬莱紫荆风电场风电机组所处的特殊雷电环境以及遭受雷击后果的分析,依据《建筑物防雷设计规范》、《建筑物电子信息系统防雷技术规范》等国家现行防雷技术规范,参照国际电工委员会(IEC)防雷部分相关标准,对风电机组雷电防护进行设计和探讨,以期达到各系统的正常运行,最大限度地减少雷击损失。Through the analysis of special lightning evironment and stroke consequence of wind turbine generator in Penglai Zijing wind power plant, according to Building lightning Protection Design Code, Electronie Information System of Building Lightning Protection Technical Specifications and other eountries the current lightning protection technology specification, with reference to lightning protection part of the relevant International Electrotechnical Commission (IEC) standards, the design and research on wind turbine lightning protection was done. Through the design of lightning protection for wind turbines, it can maintain the normal operation of the system, and minimize the loss caused by lightning strike.
分 类 号:TM614[电气工程—电力系统及自动化] TU895[建筑科学]