检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《医疗卫生装备》2014年第4期82-83,105,共3页Chinese Medical Equipment Journal
摘 要:目的:在医用高频电刀的质量控制工作中掌握高频电刀的检测方法。方法:采用德国S.P.L公司的400型高频电刀检测仪对某院的高频电刀进行检测。结果:通过检测,得出高频电刀总合格率以及引起输出功率和高频漏电流不合格的原因。结论:必须定期对高频电刀进行检测,以提高其在临床使用中的安全性。Objective To make clear the quality detection method of medical high-frequency electrotomc. Methods Type 400 detection instrument from Germany S.P.L company was used to test the high-frequency electrotome in some hospital.Results The total qualified rate of the high-frequency electrotome was found out, and the factors for unqualified output power and leak current were also determined. Conclusion Periodical detection of high-frequency electrotome has to be performed for its clinical safety.
分 类 号:R318.6[医药卫生—生物医学工程] TH777[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33