X射线荧光光谱法测定铬质引流剂的化学成分  被引量:3

Testing the Chemical Component of Chrome Condition Agent by X-ray Fluorescence Spectroscopy

在线阅读下载全文

作  者:陈德 

机构地区:[1]攀钢集团西昌钢钒有限公司技术质量部,四川西昌615000

出  处:《重庆科技学院学报(自然科学版)》2014年第3期89-92,156,共5页Journal of Chongqing University of Science and Technology:Natural Sciences Edition

基  金:国家中小企业创新基金项目"冶金性能检测技术服务平台"(12C26245116128)

摘  要:根据铬质引流剂难熔、难以制备玻璃熔片的特点,对熔剂选择和混合熔剂比例选择、试样量熔剂量比例选择、脱模剂选择用量试验、熔制程序干扰校正等进行了试验,建立了X射线荧光光谱法,以此测定了铬质引流剂的化学成分。各成分测试标准偏差≤0.12%,与化学法测定结果无显著性差异。Because Chromium is difficult to melt, it can't be made glass fuse piece. So we build X -ray fluores-cence spectroscopy to test the chemical component of chrome conduction agent to choose between flux and blending ratio, between sample volume and flux ratio, between release agent and dosage test, between melting process and interference correction. The testing standard deviation about the aboved are less than 0.12%, which is not obvious difference

关 键 词:X射线 光谱法 测定 化学成分 

分 类 号:TF11[冶金工程—冶金物理化学]

 