降低超高压高炉煤气锅炉排烟温度的研究和实践  被引量:3

Researches and Practices to Reduce the Exhaust Gas Temperature of Ultra-high Pressure Blast Furnace Gas Boilers

在线阅读下载全文

作  者:陶红卫[1] 岳洪[1] 张新育[2] 于飞[3] 

机构地区:[1]宁波钢铁有限公司余能发电厂,宁波315807 [2]宁波诺丁汉大学,宁波315100 [3]上海发电设备成套设计研究院,上海200240

出  处:《发电设备》2014年第3期169-172,共4页Power Equipment

摘  要:通过对高炉煤气和一台150t/h高炉煤气锅炉烟气成分的分析,探讨了空气预热器低温腐蚀的原因,研究了在避免低温腐蚀的前提下降低超高压400t/h煤气锅炉排烟温度的可行性。结果表明:分体式热管煤气加热器可有效降低超高压煤气锅炉排烟温度,并避免低温腐蚀,对中低压煤气锅炉的设计与改造也具有借鉴意义。Based on analysis of the blast furnace gas, the flue gas of a 150 t/h blast furnace gas-fired boiler and the low-temperature corrosion of the air preheater, the feasibility to further reduce the exhaust gas temperature of 400 t/h ultra-high pressure gas boilers was studied on the premise of avoiding low- temperature corrosion. Results show that the split-type heat pipe gas heater can effectively reduce the flue gas temperature of ultra-high pressure gas boilers and can simultaneously avoid the low-temperature corrosion, which is also of great significance for the design and retrofit of low- and medium-pressure gas boilers.

关 键 词:锅炉 高炉煤气 排烟温度 低温腐蚀 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 