检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:董豪才 邹水洋[1] 杜怡乐 吕华伟[1] 孙树高 王珍[1]
机构地区:[1]东莞理工学院化学与环境工程学院,广东东莞523808
出 处:《广东化工》2014年第9期143-144,共2页Guangdong Chemical Industry
基 金:广东省大学生创新训练项目(1181912027)
摘 要:基于电镀废水有机污染物的复杂性,采用活性污泥法和铁粉-Fenton法联合处理电镀废水。实验结果表明:驯化的活性污泥在添加1.6 g/L硫酸铵作为氮源,pH 7.2的电镀废水中,摇瓶培养72 h,废水CODCr去除率达到30%以上,但还未达到排放标准。继续用铁粉-Fenton法对处理后电镀废水上清液进行氧化处理,在H2O2用量为0.5%,加入过量铁粉,pH 3.0,25℃处理120 min,废水CODCr的去除率达到64.66%,最终降低到35.62 mg/L,低于CODCr排放标准限值。Combined activated sludge and Fenton oxidation processing was employed to treat electroplating wastewater that contained complex organic contaminants. The experimental results showed that the removal rate of CODcr reached over 30 % in an optimized processing with domesticated sludge cultured in shake-flask for 72 h, 1.6 g/L ammonium sulfate as nitrogen source and pH as 7.2. The supematant liquid of wastewater after activated sludge treatment was sequentially treated by iron-Fenton technique under optimal conditions as follows: 0.5 % H2O2 and excessive iron powder, pH=3.0, 25 ℃ for 120 min. Finally the CODcr removal rate reached 64.66 %, and the CODer eventually reduced to 35.62 mg/L, which has reached the emission standard.
关 键 词:微生物 电镀废水 有机污染物 CODCR FENTON试剂
分 类 号:X5[环境科学与工程—环境工程]