检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《中国农村水利水电》2014年第5期101-104,共4页China Rural Water and Hydropower
基 金:江苏省产学研联合创新资金项目(BY2012007);江苏省水利科技重点项目(2009041)
摘 要:针对水工钢闸门吊耳框架结构复杂的情况,利用大型通用有限元软件ANSYS复核其受载结构安全。有限元仿真分析中出现的极少数单元Mises等效应力超过许用应力的结构应力集中现象,由于响应区域内材料塑性变形影响,可以引起结构应力重新分布,应当考虑线弹-塑性失效因素。通过吊耳上框架线弹-塑性失效仿真、承载考核试验等成果分析表明,结构整体呈现一定的受载耐受特性,吊耳框架具备设计承载能力。Allowing for the complex structure of lifting lug of hydraulic steel gates, this paper applies ANSYS to check the safety of the given hearing structures. Actually, there are indeed a few units whose Mises stress exceeds the allowable stress, which gives rise to stress concentration. The reason lies in the fact that the internal stress will be redistributed considering the influence of plastic deformation in responding regions. Hence, the linear elasticity-plastic failure factor needs to be taken into account. A simulation analy sis of linear elasticity-plastic failure and bearing capacity test prove that the entire structure possesses a load-enduring property to a certain degree, and the lifting lug frame is equipped with designed hearing capacity.
关 键 词:钢闸门 ANSYS有限元分析 应力集中 安全复核 逐段线弹—塑性失效
分 类 号:TV34[水利工程—水工结构工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15