MBR系统运行条件对膜污染影响研究  被引量:18

STUDY ON THE INFLUENCE OF MBR SYSTEM OPERATING CONDITIONS ON MEMBRANE FOULING

在线阅读下载全文

作  者:计根良 郑宏林[2] 周勇[2] 

机构地区:[1]上海沛杰过滤技术有限公司,上海200335 [2]杭州水处理技术研究开发中心,浙江杭州310012

出  处:《水处理技术》2014年第6期90-92,共3页Technology of Water Treatment

摘  要:膜生物反应器(MBR)是一种新型高效的污水处理工艺,但MBR中膜污染问题限制了该技术的大规模推广应用。从MBR系统运行条件入手,通过实验方式定性分析了曝气强度强弱、抽停时间占比与膜污染的关系。实验得出对应工况下,最佳曝气强度为0.4 m3/(m2·h)和最佳抽停时间比4:1。最后,将优化的运行条件应用于工程实际,经过3个月的正常运行,该MBR系统膜污染控制效果显著。Membrane Bioreactor (MBR) is a new and efficient wastewater treatment process, but the fouling restricts the large-scale popularization and application of the technology.This paper qualitativelyanalyze the relationship between the membrane fouling and theoperation conditions of MBR system such as the aeration intensity andon/offratiothrough the experiments.The experiments put forward the best aeration intensity is 0.4 m^3/(m^2· h) and the best on/off ratio is 4:1. Finally, the optimal operating condition is applied to the engineering practice. After three months of normal operation, the effectofmembrane fouling controlling is remarkable.

关 键 词:MBR 膜污染 影响因素 曝气强度 抽停时间比 

分 类 号:TQ028.8[化学工程]

 