熔盐堆非能动余热排出系统空气冷却与水冷却方案比较分析  

Comparison between Air-cooled and Water-cooled Schemes for the Passive Residual Heat Removal System of Molten Salt Reactor

在线阅读下载全文

作  者:孙露[1] 孙立成[1] 阎昌琪[1] 法丹[1] 王纳秀[2] 

机构地区:[1]哈尔滨工程大学核科学与技术学院,哈尔滨150001 [2]中国科学院上海应用物理研究所,上海201800

出  处:《核动力工程》2014年第3期18-21,共4页Nuclear Power Engineering

基  金:国家自然科学基金资助(51376052;51076034)

摘  要:以美国10 MW熔盐实验堆(MSRE)为研究对象,设计空气冷却和水冷却2种非能动余热排出系统。通过建立相应的数学模型,采用C++语言编程,分别对系统的主要特性进行研究,并对2种系统的运行特性进行比较分析。结果表明,虽然空气冷却和水冷却均能满足系统的排热要求,并能形成稳定的自然循环,但从长期冷却性能方面看,空气冷却方案的综合性能更好。The water-cooled and air-cooled passive residual heat removal systems (PRHRSs) were designed for 10MW molten salt reactor experiment (MSRE), according to which the mathematical models were established and numerically solved in the code of C++. Main characteristics of the two systems were given and compared. The results show that both water-cooled and air-cooled PRHRSs can establish stable natural circulations and meet the design requirements for heat removal. However, the air-cooled PRHRS has better comprehensive performance for long term cooling.

关 键 词:熔盐堆 空气冷却 水冷却 非能动 余热排出系统 

分 类 号:TL334[核科学技术—核技术及应用]

 