作 者:汤伟军[1] 范卫君[1] 胡宙[1] 陈星荣[1] 沈天真[1] 辛军
机构地区:[1]上海复旦大学医学院华山医院放射科,200040 [2]北京北陆医药化工集团
出 处:《中国医学计算机成像杂志》2000年第6期415-418,共4页Chinese Computed Medical Imaging
摘 要:目的:寻求一种能安全有效地用于DSA的含碘造影剂的代用品。材料和方法:(1)体外试验:对不同浓度的磁显葡胺(Gd-DTPA)及Omnipaque分别进行不同条件下的CT扫描,并分别测定各自的CT值,得出浓度-CT值曲线和回归方程,然后根据回归方程计算两种造影剂间的等效浓度和衰减比值。(2)体内试验:用0.5mol/L,0.25mol/L,0.17mol/L的Gd-DTPA及300mgI/ml的Omnipaque作为造影剂对16只随机分为四组的新西兰大白兔分别进行腹主动脉插管、主动脉、锁骨下动脉、腹主动脉、肠系膜上动脉造影,造影结果分四级进行记录。结果:体外实验中,0.5mol/L的Gd-DTPA的CT值相当于80~100mgI/ml的Omnipaque,其产生的X线衰减为相同浓度Omnipaque的2.58~3.06倍,随扫描电压条件提高,Gd-DTPA衰减值的下降要小于Omnipaque。在体内试验中,对于中、小动脉,两种造影剂效果均较满意, 0.5mol/L的Gd-DTPA与300mgl/ml的Omnipaque间无明显统计学差别(p> 0.05),对于较粗大动脉,三种浓度Gd-DTPA的造影效果均较差,?To seek a safety and effective alternative noniodinated contrast media for DSA. Materials and Methods: In vitro,serial dilution of Gd-DTPA and Omnipaque were placed in a CT scanner (Shimazu 5000), ROI attenuation measurements were made from 5mm thick axial section (80/ 120 /130kV, 160mA, 2s). And the concentration-CT value curves and regression equations were obtained. The equivalent concentration and attenuation ratio of these two contrast media were calculated by the equations. In vivo, 16 rabbits, which were 2.5 - 3.5kg in weight, were divided into four groups ramdonly. Then aorta, subclavian artery, abdominal aorta and supramenstric artery angiography were undergone with 0.5mol/L, 0.25mol/L, 0.17mol/LGd-DTPA and 300mgI/ml Omnipaque separately. The angiography results were recorded in four grades. Results: The attenuation of 0.5mol/L Gd-DTPA was equal to that of 80 - 100mgI/ml Omnipaque, and was 2.58 - 3.06 times as the same concentration of 300mgI/ml Omnipaque. With the increase of the kV, the fall of attenuation of Gd-DTPA was less than that of Omnipaque. The middle and small arteries of the rabbits were good visualized when undergone DSA with 0.5moI/L Gd-DTPA and 300mgllml Omnipaque, no statistic difference between those with these two contrast media(p>0.05). The big arteries were poor visualized with Gd-DTPA, statistic difference between those with Gd-DTPAand with Omnipaque(p<0.05). Conclusion: To small and middle arteries using Gd-DTPA as an alternative contrast media for DSA is acceptable, but the clinical use still needs futher study.
分 类 号:R814.43[医药卫生—影像医学与核医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222