Performance of a New Ion Source for KSTAR Tokamak Plasma Heating  

Performance of a New Ion Source for KSTAR Tokamak Plasma Heating

在线阅读下载全文

作  者:Tae-Seong KIM Seung Ho JEONG Doo Hee CHANG Kwang Won LEE Sang-Ryul IN 

机构地区:[1]Korea Atomic Energy Research Institute

出  处:《Plasma Science and Technology》2014年第6期620-624,共5页等离子体科学和技术(英文版)

摘  要:In the experimental campaign of 2010 and 2011 on KSTAR, the NBI-1 system was equipped with one prototype ion source and operated successfully, providing a neutral beam power of 0.7-1.6 MW to the tokamak plasma. The new ion source planned for the 2012 KSTAR campaign had a much more advanced performance compared with the previous one. The target performance of the new ion source was to provide a neutral deuterium beam of 2 MW to the tokamak plasma. The ion source was newly designed, fabricated, and assembled in 2011. The new ion source was then conditioned up to 64 A/100 keV over a 2-hour beam extraction and performance tested at the NB test stand (NBTS) at the Korea Atomic Energy Research Institute (KAERI) in 2012. The measured optimum perveance at which the beam divergence is a minimum was about 2.5μP, and the minimum beam divergent angle was under 1.0° at 60 keV. These results indicate that the 2.0 MW neutral beam power at 100 keV required for the heating of plasma in KSTAR can be delivered by the installation of the new ion source in the KSTAR NBI-1 system.In the experimental campaign of 2010 and 2011 on KSTAR, the NBI-1 system was equipped with one prototype ion source and operated successfully, providing a neutral beam power of 0.7-1.6 MW to the tokamak plasma. The new ion source planned for the 2012 KSTAR campaign had a much more advanced performance compared with the previous one. The target performance of the new ion source was to provide a neutral deuterium beam of 2 MW to the tokamak plasma. The ion source was newly designed, fabricated, and assembled in 2011. The new ion source was then conditioned up to 64 A/100 keV over a 2-hour beam extraction and performance tested at the NB test stand (NBTS) at the Korea Atomic Energy Research Institute (KAERI) in 2012. The measured optimum perveance at which the beam divergence is a minimum was about 2.5μP, and the minimum beam divergent angle was under 1.0° at 60 keV. These results indicate that the 2.0 MW neutral beam power at 100 keV required for the heating of plasma in KSTAR can be delivered by the installation of the new ion source in the KSTAR NBI-1 system.

关 键 词:NBI ion source KSTAR neutral beam plasma heating positive based ion 

分 类 号:TL631.24[核科学技术—核技术及应用] TQ174[化学工程—陶瓷工业]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象