机构地区:[1]广东省罗定市妇幼保健院儿科,广东罗定527200
出 处:《中国医药科学》2014年第7期131-133,共3页China Medicine And Pharmacy
摘 要:目的探讨桡动脉采血和股动脉采血两种采血法在新生儿科应用中的临床效果。方法将我院儿科NICU收治200例患儿随机分为观察组和对照组(各100例),观察组采用桡动脉采血法采集血气标本,对照组采用股动脉采血法采集血气标本。结果观察组一次穿刺成功率明显高于对照组(P<0.05),误入静脉率明显低于对照组(P<0.05),发生血肿或瘀斑的比例均较之对照组低(P<0.05),重度疼痛率明显低于对照组(P<0.05);且观察组穿刺时间明显短于对照组,两组比较差异具有统计学意义(P<0.05)。结论桡动脉采血较之股动脉采血时对患儿的不良影响明显要小,具有操作方便、安全、简单、穿刺成功率高等优点,值得推广应用。Objective To investigate clinical effect of radial artery and femoral artery blood sampling method which were used to neonatology.Methods 200 cases of children were randomly divided into observation and control group(each of 100 cases),who received treatment in our pediatric NICU. Radial artery blood method was taken to collect blood samples of observation group,and femoral artery blood method was taken to collect blood samples of control group. Results Successful rate of puncture of observation group was Significantly higher than control group(P〈0.05). Vein strayed rate was Significantly lower than control group(P 〈0.05).Proportion of hematoma or ecchymosis was lower than control group(P〈0.05). Severe pain was significantly lower than the control group (P〈0.05). Puncture time of observation group was also significantly shorter than the control group,with a statistically significance(P〈0.05). Conclusion Compared with femoral artery blood,adverse effects on children of radial artery blood is significantly smaller. Its advantages conclude convenient operation,safety,simple and puncture success rate,which is worthy of application.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.198