检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李历波[1] 康鸿飞[1] 梁健[1] 邹凤林 杨思安
机构地区:[1]重庆市电力公司綦南供电局,重庆400014 [2]深圳市泰昂科技股份有限公司,广东深圳518057
出 处:《电源技术》2014年第6期1118-1119,共2页Chinese Journal of Power Sources
摘 要:针对变电站直流电源系统,采用间接并联等前沿技术研究的系统替代传统的蓄电池组和充电机作为直流电源产品。含间接并联技术的系统采用DC12 V/DC220 V或者DC12 V/DC110 V模块,配置12 V阀控密闭铅酸蓄电池,配置相应的交流屏提出并联电池一体化电源解决方案。新技术的应用,大量减少了蓄电池使用量,是低碳环保的体现,提高了电网的社会责任。Focusing on DC power system of transformer substation, a new system including latest researched indirect parallel technology of power module was used to substitute the traditional DC power including charger and battery pack. The system containing indirect parallel technology consisted of DC 12 V/DC 220 V or DC 12 V/DC 110 V module with one 12 V valve-regulated sealed lead acid battery, adding relevant AC panel, then parallel battery incorporate power solution was proposed. The use of these new technology can decrease the number of battery in DC power system, playing a role in environmental protection, and improving the social responsibility of power grid.
分 类 号:TM912[电气工程—电力电子与电力传动]