摘 要:目的探讨256排CT应用低剂量对比剂肺动脉成像的临床应用价值。方法应用256排CT对临床疑诊肺动脉栓塞102例患者进行肺动脉成像,总对比剂量为25 mL(370 mgI/mL),对比剂跟踪技术启动扫描,采用最大密度投影(MIP)、曲面重建(CRP)技术显示肺动脉及其分支,评价成像质量能否满足临床诊断需要。结果肺动脉增强后左右肺动脉干CT值均≥260 Hu,占93.1%,检出肺动脉栓塞17例。结论 256排CT低剂量对比剂肺动脉成像检查,图像质量可以满足临床诊断需要,对确诊肺动脉栓塞具有很高的临床应用价值。Objective To investigate the performance of 256-slice CT pulmonary artery angiog raphy(CTPA) with low dose contrast medium. Methods 102 patients known to suspect of having pulmonary embolism under went 256-slice CTPA with 25 mL contrast medium. Use contrast media Tracking technology start-up scanning,Maximum intensity projection(MIP),curved-planar reconstruction (CPR)were used to display pulmonary arteries,We evaluated the image quality of pulmonary artery to estimate if the examination can fulfill the clinical demand. Results There were 93.1% of patients whose CT values detected in the pulmonary artery after enhancement were ≥260hu.There were 17 cases with pulmonary embolism. Conclusion 256-slice CT pulmonary artery angiog raphy (CTPA) with low dose contrast medium could depict pulmonary artery with good image quality .It has great potential in the etiological diagnosis for the patients with pulmonary embolism.