检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈建华[1] 宋阳[1] 张颖[1] 岑为[1] 魏新宇[1] 黄文氢[1]
机构地区:[1]中国石油化工股份有限公司北京化工研究院,北京100013
出 处:《分析试验室》2014年第7期851-854,共4页Chinese Journal of Analysis Laboratory
摘 要:采用ICP-MS以无水氯化镁、碳镁摩尔为5~8:1的氯化镁醇合物丙烯聚合催化剂载体和碳镁摩尔比为12:1的六乙醇合氯化镁为对象,分别在普通模式、He模式下采用外标曲线加内标校正法和He模式下标准加入法测定其中的镁含量,并取几个典型样品采用ICP-OES进行镁含量测定。考察了采用ICP-MS测定丙烯聚合催化剂载体中镁含量时碳可能产生的影响。实验结果表明,对于碳镁摩尔比从5~8∶1到12∶1样品,碳对镁含量分析的影响均很小,其镁含量均可以在普通模式下采用外标曲线加内标校正法进行快速、简单、准确的测定。In this article,the potential effect of carbon on magnesium content determination by ICP-MS was investigated.Magnesium contents of MgCl2,supports(C/Mg molar ratio 5 ~8:1) for propylene polymerization catalysts and MgCl2·6C2H5OH were determined by ICP-MS under normal mode,He mode and standard addition method under He mode.The data obtained by ICP-MS was compared with that obtained by ICP-OES.The results indicated that carbon had little effect on magnesium content analysis when the mole ratio of carbon to magnesium ranged from 5 ~ 8:1 to 12:1 and accurate magnesium contents in supports could be obtained simply by ICP-MS under normal mode by external standard calibration combined with internal standard calibration.