清远抽水蓄能电站上水库事故检修闸门充水阀设计探讨  被引量:7

Discussion on the Design of Filling Valve for the Upper Reservoir Emergency Gate of Qingyuan Pumped-storage Power Station

在线阅读下载全文

作  者:肖段龙[1] 周育桢 董笑波 

机构地区:[1]广东省水利电力勘测设计研究院,广东广州510635 [2]国家电网节能服务有限公司,北京100052 [3]河北省桃林口水库管理局,河北秦皇岛066400

出  处:《水力发电》2014年第7期79-81,共3页Water Power

摘  要:在改进惠州抽水蓄能电站上水库事故检修闸门充水阀基础上,经理论计算与分析,提出了清远抽水蓄能电站上水库事故检修闸门上设置充水阀的数量、规格,并推导了充水阀流量和开度的相互关系,以指导不同水位时对充水阀的操作控制。Based on the actual improvement of the filling valve for the upper reservoir emergency gate of Huizhou Pumped-storage Power Station, the numbers and technical parameters of the filling valve for the upper reservoir emergency gate of Qingyuan Pumped-storage Power Station are proposed by theoretically analysis and calculation. The relationship between the flow and opening of filling valve is also derived to guide the operation of filling valve under different water level.

关 键 词:水道充水 充水阀 流量 清远抽水蓄能电站 