城镇给水厂集约化设计实例  被引量:6

An example of integrated design for urban water supply plant

在线阅读下载全文

作  者:王晏[1] 

机构地区:[1]上海市政工程设计研究总院(集团)有限公司,上海200092

出  处:《工业用水与废水》2014年第3期63-67,共5页Industrial Water & Wastewater

基  金:水体污染控制与治理科技重大专项(2012zx07403-002);国家科技支撑计划(2012BAJ25B02-01);上海市青年科技启明星计划(B类)资助(13QB1403300)

摘  要:基于全流程、全立体、全厂界的给水厂集约化理念,针对城镇中心城区超大型水厂原址的升级改造工程,采取了高效工艺优化、功能的拓展集成、紧凑的总图布置、空间的三维利用等方法,各个单元之间组合出叠合式、组团式、合建式等综合池型,有效提高了土地利用率,万吨水占地面积指标为1 600 m2。建成运行后,出厂水水质指标达到GB 5749—2006《生活饮用水卫生标准》,其中浊度≤0.1 NTU、色度≤5倍、ρ(CODMn)≤1.5mg/L、ρ(NH3-N)≤0.3 mg/L、ρ(Mn)≤0.05 mg/L。Based on the idea of intensification design for water supply plant, which was represented by full-flow process, three-dimensional and boundary control, an upgrading reconstruction project of ultra-large type water supply plant located in central urban area was carried out adopting the measures of high efficient process optimization, functional expansion and integration, layout combination, utilization of three-dimensional space and so on. According to different space conditions, pools with types of composite, group and combined construction were built among different units, which effectively improve the utilization rate of the land, and the land demand for the treatment of 10 000 tons of water was 1 600 m2. Through the reconstruction, the turbidity, chroma and mass concentrations of CODMn, and ammonia nitrogen in the effluent water were not above 0.1 NTU, 5 times,1.5, 0.3 and 0.05 mg/L respectively, which could meet the specification of GB 5749—2006 Standards for Drinking Water Quality.

关 键 词:集约化设计 升级改造 水厂 节约用地 

分 类 号:TU991.35[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象