检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴爽[1,2] 周长圣[1] 张龙江[1] 顾海峰[1] 祁丽[1] 黄伟[1]
机构地区:[1]南京军区南京总医院医学影像科,南京210002 [2]徐州医学院研究生学院,江苏221004
出 处:《放射学实践》2014年第6期606-609,共4页Radiologic Practice
摘 要:目的:评价70kV管电压CT血管成像在诊断儿童胡桃夹综合征中的应用价值。方法:27例临床疑似胡桃夹综合征的患者进行了新双源CT 70kV CT动静脉混合期血管成像(70kV组),另37例患者行120kV腹部增强双期扫描(120kV组)。测量患者左肾静脉、肠系膜上动脉、腹主动脉、腰大肌的CT值及皮下脂肪的标准差并计算图像的信噪比(SNR)和对比噪声比(CNR)。两名放射科医师对所有病例以四分法进行评分。计算有效剂量(ED)。比较两组间的图像质量及辐射剂量。结果:70kV组左肾静脉的CT值、SNR及CNR明显高于120kV组,差别有统计学意义(P<0.01),70kV组肠系膜上动脉、腹主动脉的CT值、SNR及CNR与120kV动脉期组比较差别无统计学意义(P>0.05),与120kV静脉期组比较明显提高,差别有统计学意义(P<0.001)。70kV组图像质量主观评分高于120kV组,与120kV动脉期组比较差别无统计学意义(P=0.137),与120kV静脉期组比较差别有统计学意义(P<0.001)。70kV组辐射剂量与120kV组比较明显降低,有效辐射剂量降低了93.7%,差异有统计学意义(P<0.001)。结论:临床疑似胡桃夹综合征的儿童70kV动静脉混合期CT血管成像在保证图像质量满足诊断的同时大幅降低了辐射剂量。Objective:To assess the diagnostic value of CT angiography at 70kV in children with nutcracker syndrome.Methods:27 subjects with clinically suspected nutcracker syndrome underwent CT scanning at 70kV (70kV group) and the other 37 subjects underwent CT dual-phase abdominal enhancement scanning at 120kV (120kV group).The CT values of left renal vein,superior mesenteric artery,abdominal aorta,psoas muscle and the standard deviation of subcutane-ous fat were measured and the signal-to-noise ratio (SNR)and contrast-to-noise ratio (CNR)of the images were also calculated for each patient.Two radiologists evaluated the image quality using a 4-point scale and calculated each effective dose (ED).The differences of radiation dose and image quality between two groups were compared.Results:The 70kV group showed higher CT values,SNR and CNR of left renal vein than the 120kV group (P〈0.01),and the CT values,SNR and CNR of superior mesenteric artery and abdominal aorta in 70kV group were significantly higher than those in 120kV venous phase group (P〈0.001),but there was no statistical difference between 70kV group and 120kV arterial phase group (P〉0.05).The subjective score of image quality in 70kV group was higher than 120kV group,but there was no significant difference between 70kV group and 120kV arterial phase group (P= 0.137),while there was significant difference between 70kV group and 120kV venous phase group (P〈0.001).Compared with 120KV group,the radiation dose was significantly lower in 70kV group,and the effective radiation dose was reduced by 93.7% (P〈0.001).Conclusion:70kV mixed phase CT angiography can effectively reduce the radiation dose while maintaining image quality in children with clinically suspected nutcracker syndrome.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.135.248.144