检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:沈军[1]
机构地区:[1]首钢京唐钢铁联合有限责任公司,河北唐山063200
出 处:《冶金动力》2014年第6期8-10,共3页Metallurgical Power
摘 要:某炼钢厂LF炉所用的SVC装置发生PT高压保险熔断、避雷器频频动作、电缆头放炮等异常运行情况。对这一现象进行了深入分析,认为是由于FC滤波支路失谐度过大造成的,并提出了相应的对策和建议,以保证SVC装置的安全可靠性。Abnormal operating conditions such as PT high voltage fuse burning out, ac-tion of lightening arrester and cable head sparking occurred in the SVC device for the LF furnace in a steel plant. Through deepened analysis it was found that the phenomenon was caused by excessive detuning in the FC filter circuit. Relevant countermeasures and sugges-tions were also put forward, to ensure the safety and reliability of the SVC device.
分 类 号:TM714.3[电气工程—电力系统及自动化]