操作条件及运行通量对超滤膜污染的影响  被引量:5

Influence of different operating conditions and fluxes to membrane fouling

在线阅读下载全文

作  者:何青[1] 李圭白[2] 吕谋[1] 孟聪[1] 陈超[1] 

机构地区:[1]青岛理工大学环境与市政工程学院,青岛266033 [2]哈尔滨工业大学市政环境工程学院,哈尔滨150001

出  处:《青岛理工大学学报》2014年第3期94-99,共6页Journal of Qingdao University of Technology

基  金:国家水污染控制与治理重大专项资助项目(2008ZX07422-005)

摘  要:从优化操作工艺和摸索长期运行零污染通量2个角度对浸没式超滤膜污染进行了研究.结果表明:曝气强度为40m3/(m2·h)时,对膜污染的去除可取得良好的效果;运行周期越短,膜污染越轻;存在一个通量范围,在此范围内,TMP和膜阻力随时间增长缓慢,一旦超出了这个范围,TMP和膜阻力便会随时间增长迅速增加.The paper has an experience of ultrafiltration membrane at different operating conditions and different fluxes, which aims at having a studying on the ultrafiltration fouling. It shows that the 40 m^3/(m^2· h) gas intensity plays a very good effect on membrane fouling removal. The shorter the selected operating cycle is, the lighter the membrane fouling will be. And there is a range of flux. Under the flux, transmembrane pressure will increase very slowly. But if the flux exceeds it, transmembrane pressure will increase rapidly.

关 键 词:超滤膜 运行条件 长期运行 通量 膜污染 

分 类 号:TU991.2[建筑科学—市政工程]

 